EcoZone - Natural Ecosystems for Healthy Pets

0 Items In Cart  $0.00 | Checkout

EcoZone Vivarium Controllers

Simulate the Rhythm and Cycles of Nature

Variety is the Spice of Life ... so why should your herps live in a stagnant, unchanging vivarium ecosystem? Wouldn’t life be dull if every day sunrise and sunset occurred at exactly the same time, and with exactly the same intensity? Every day a steady 86 degrees with 76 degrees at night? The change from day to night/night to day, always at exactly 8:00am and 8:00pm 365 days a year?

It doesn’t have to be that way for your herps! The EcoZone Vivarium controller provides complete programmability over a 24 hour day and 12 month year, AND easy setup, for the most realistic vivarium ecosystem ever!

Programmable automated proportional power control of 4 AC line outputs, plus monitor/control with up to 4 Humidity and/or Temperature Sensors, (up to 4 Humidity and 4 Temperature readings per device). Program modes include Dusk/Dawn lighting, Proportional Heat/Cool cycles, Lunar cycles, and Humidity controlled as well as timed mister / humidifier controls.

Click HERE to read what others say about the Ez400 vivarium Controller.

Shop for Vivarium Controllers

Additional Information

User Guide | Datasheet | FAQ | Ez400 Web Interface LIVE Demo

Front View

 

Rear View

Features

Specifications

EcoZones

• Rainforest • Woodlands • Dessert • Savannah • 4-Line Heater

AC Line Modes

Dusk Dawn Lighting Mode
• On and Off Time of Day
• Ramp Duration (minutes, 0-240)
• Max Power (10%-100%)
• Min Power on ramp-down
(10% - 100%)

Basking Spot Lighting Mode
• On & Off Time of Day
• Ramp Duration (minutes, 0-240)
• Max Power (10%-100%)
• Min Power on ramp-down
(10% - 100%)

Lunar Lighting Mode
• On & Off Time of Day
• New Moon Day (dd/mm/yyyy)
• Max Power Full Moon (10%-100%)
• Min Power New Moon
(10% - 100%)

Interval Timer Mode
• 6 On & Off Chcles Per Day

Cooling Mode
•Temperature High
•Temperature Low
•Temperature High & Low Time of Day
• Control Mode (Proportional, on/off)
• Proportional Mode Power Level
(Low, Med, High)
• Hysterisis (1 deg - 5 deg)
• Control Temp Probe # (1-4)

Heater Mode
•Temperature High
•Temperature Low
•Temperature High & Low Time of Day
• Control Mode (Proportional, on/off)
• Proportional Mode Power Level
(Low, Med, High)
• Hysteresis (1 deg - 5 deg)
• Control Temp Probe # (1-4)

Timed Mister Mode
• On Time of Day (up to 6 times/day)
• Mist Duration (seconds, 1-295)

Auto Mister Mode (Ez400-RHT)
• Humidity High & Low Set Points (10% - 100%)
• Humidity High & Low Time of Day
•Programmable Rh check interval (minutes, 1-300)
• Mist Duration (seconds, 1-295)
• Manual Mist Override (up to 6 times/day)
• Hysteresis (1% - 10 % Rh)
• Control RHT Probe # (1-4)

Auto Humidity Mode (Ez400-RHT)
•Humidity High & Low Set Points (10% - 100%)
• Humidity High & Low Time of Day
• Hysteresis (1% - 10 % Rh)
• Control RHT Probe # (1-4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Input/Output Modes

I/O Input
• Alarm Trigger Mode
• Input Trigger Mode (trigger AC line shutoff, IO output, or both)

I/O Output
• Timed On/Off Output (up to 6 cycles per day)
•Flasher/Strobe Mode (storm simulation)

 

 

 

 

 

 

Unit Features

Alarms
• OverTemp and UnderTemp Alarms - w/ Programmable Temperature Threshold
• Input Trigger Alarm Mode
Alarm Actions: Audible, Shutdown, Audible + Shutdown

Remote Management & Control
• Software Upgradable - Never Obsolete!
• HTTP Web Interface
Monitor temperature, lighting, operation. Web browser based setup. Advanced features.

 

 

 

 

 

 

 

Hardware Specifications

AC Line Outlets (4)
• 110/120VAC 4A (450W)
• Dimmable 10-100% (5% increments)
• Safety Ground

Misc
10/100 Ethernet HTTP interface

Probe Inputs (4)
• Temperature -20 - 160 Deg +/- 1 Deg Fahrenheit or Celsius
• Humidity 0 - 100 % +/- 3% Rh - (Ez400-RHT w/ Digital RHT Probe)

Input / Output (1)
• Input Contact Open, Contact Closed (selectable)
• Output Normally Open, Normally Closed
• Output Isolated Relay Contacts 24V 2A Max